WATER TREATMENT PRODUCT FINDER

Water treatment chemicals,
selected by problem.

From cooling-water scale and metal corrosion to membrane fouling, heavy metals, ammonia nitrogen, total phosphorus, colour, foam and odour — identify the treatment target first, then the product, then verify the dose.

  • 22 product families
  • Physical and pH parameters
  • Dosing points and trial guidance
Drums of industrial water treatment chemicals in storage and dispatch
PRODUCT CATALOGUE Scale · Cleaning · Metals · Ammonia · Colour
01

The same wastewater category is not the same water chemistry. Selection needs a water report, system materials, flow, target values and the existing process.

Scale & corrosionCooling water / RO / boiler
Cleaning & prefilmingMembranes / exchangers / pipework
Pollutant removalMetals / ammonia / phosphorus / colour
Process auxiliaryBiocide / foam / odour / FGD

QUICK ANSWER

Not sure which product fits?

Narrow the range with treatment target + system type. For scale and corrosion, start with a corrosion and scale inhibitor or a boiler scale inhibitor. For falling membrane flux, diagnose the fouling type before choosing a cleaner. Heavy metals, ammonia nitrogen, phosphorus and colour should each be verified against their own analytical target. For biofilm, foam and odour, find where they are generated, then choose a biocide, slime stripper, defoamer or deodoriser.

Open the problem-to-product table

APPLICATION SCENARIOS

Different systems,
different priorities.

Application decides chemical compatibility, dosing point and the indicators to monitor. The notes below are for first screening; the final programme depends on water quality, materials, process and discharge rules.

Drums of cooling water treatment chemicals in storage 01 / CIRCULATING WATER

Circulating cooling water

Managing scale, corrosion and microbiology together

In power, chemical, petrochemical, steel and HVAC cooling systems the priorities are heat-transfer efficiency, carbon-steel and copper corrosion, microbial control and slime deposition.

  • Scale and corrosion: corrosion and scale inhibitor, copper inhibitor, prefilming agent
  • Microbiology and slime: oxidising / non-oxidising biocide, slime stripping agent
  • HVAC: dedicated circulating-water chemical and system cleaning
View the related products
02

RO / NF / UF

RO antiscalant, acid cleaner and alkaline cleaner for membrane systems

Membrane antiscaling and cleaning

Calculate antiscalant dose from feed salinity, temperature, recovery and membrane type. After fouling, identify scale, organic or microbial deposit first, then choose the acid or alkaline route.

  • Prevent membrane scaling
  • Protect CA, TFC, NF and UF membranes
  • Monitor pH, differential pressure and permeate flow
03

BOILER / HEAT EXCHANGER

Boiler scale inhibitor and industrial scale remover in drums

Boilers and heat-exchange equipment

Boiler feed and circulating water need scale control, corrosion control, blowdown and operating pH in balance. Industrial scale remover suits shutdown or circulating cleaning after material and deposit checks.

  • Boiler scale prevention and water control
  • Heat-exchanger and condenser descaling
  • Prefilming after cleaning
04

METAL FINISHING

Heavy metal catcher and organic sulfur for electroplating and PCB wastewater

Electroplating, PCB, mining and metallurgy

Measure metal concentration and complexing agents first. Organic sulfur or heavy metal catcher then chelates and precipitates the metals, followed by coagulation, flocculation, sedimentation or filtration.

  • Copper, lead, nickel, zinc and chromium removal
  • Working pH usually neutral to mildly alkaline
  • Sludge disposed under local rules
05

TEXTILE / PAPER / CHEMICAL

Decolourant and phosphorus removal agent for dyeing, paper and chemical wastewater

High colour and high organic load

Colour and COD usually rise together. Decolourant is used with coagulants such as PAM, and the dosing order, pH and ratio must be set by jar test.

  • Dye, printing and textile wastewater
  • Paper, ink and pigment wastewater
  • Adjust pH before decolourising and settling
06

MUNICIPAL / LANDFILL

Ammonia nitrogen remover and phosphorus removal agent for municipal and landfill leachate

Municipal, leachate and final polishing

Ammonia nitrogen, total phosphorus and colour may need final-stage treatment. The programme must also consider sludge volume, pH swings, residuals and effects on the biological stage.

  • Ammonia nitrogen polishing
  • Phosphorus removal in domestic and industrial effluent
  • Colour treatment for landfill leachate
07

FARM / FOOD / SOLID WASTE

Plant deodoriser and silicone defoamer for odour and foam control

Odour, foam and air quality

Plant deodoriser is sprayed on odour sources and in enclosed spaces; silicone defoamer controls foam in wastewater, paper, textile, cleaning and fermentation.

  • Livestock, aquaculture and waste odour
  • Wastewater and industrial cleaning foam
  • Find the foam and odour source first
08

FLUE GAS / PROCESS AUXILIARY

Desulfurisation and process auxiliary

Desulfurisation synergist and reducing agent must be applied against gas or wastewater figures, reaction conditions and compatibility, never mixed with strong oxidisers or incompatible materials.

  • Wet FGD projects in thermal power
  • Reduction, dechlorination or sulfide control
  • Dose from jar test and process conditions
09

PROJECT SUPPORT

It is more than buying a drum of chemical

The same product name can behave differently with water quality, concentration and formulation. Complete information at inquiry stage is what makes an executable recommendation possible.

Prepare your inquiry

DECISION TABLE

Problem, product and what to verify

Use this as a project screening list. A dose cannot be read from "kilograms per tonne" alone — concentration, pH, temperature and contact time all change the result.

Field problemProducts to check firstData requiredIndicator to verify
Cooling-water heat-exchanger scalingCorrosion and scale inhibitor, boiler scale inhibitorMakeup and circulating water analysis, materials, holding volumeTurbidity, hardness, pH, heat-transfer efficiency, differential pressure
RO membrane flux declineRO antiscalant, acid / alkaline cleanerFeed salinity, temperature, recovery, membrane type, differential pressurePermeate flow, salt rejection, differential pressure, cleaning pH
Pipework and metal corrosionCorrosion and scale inhibitor, copper inhibitor, prefilming agentCarbon steel / copper / stainless ratio, velocity, water qualityCorrosion rate, iron and copper content, film condition
Heavy metals above limitOrganic sulfur, heavy metal catcherMetal concentration, complexes, pH, flowResidual metal, floc size, settling rate
Ammonia nitrogen or total phosphorus highAmmonia nitrogen remover, phosphorus removal agentInitial concentration, target, flow, coexisting ionsAmmonia, total phosphorus, pH, residual and sludge volume
High wastewater colourDecolourantColour, COD, dye or paper type, pHColour removal, COD, turbidity, settling
Excess foam and odourSilicone defoamer, plant deodoriserFoaming system, temperature, odour source, spray environmentFoam height, persistence, sensory and gas readings
Algae and biological slimeOxidising / non-oxidising biocide, slime stripping agentColony count, slime volume, reducing substances, materialsTotal colony count, slime removed, corrosion risk

PRODUCT CATALOGUE

22 product families,
compared by parameter.

Open a card for catalogue parameters, typical systems and use notes. Every dose must be checked against water quality, process and product version — it does not replace a site trial.

Showing 22 products

P-01Cooling water

Corrosion & Scale Inhibitor

Organic phosphonate, polycarboxylate and steel/copper inhibitor blend that disperses calcium carbonate, calcium sulfate and calcium phosphate while protecting metal surfaces.

View catalogue parameters and use notes
Appearance
Pale-yellow to amber liquid
Solids
21–32%
pH
3.0 ± 1.5
Reference dose
10–30 mg/L on makeup water

Dose continuously at the circulating-pump inlet or sump outlet with a metering pump. Used in power, chemical, petrochemical and steel circulating cooling systems.

P-02Membrane

RO Antiscalant

Membrane scale inhibitor for RO, NF and UF systems, compatible with CA and TFC membranes. Reduces cleaning frequency and the acid-dosing corrosion risk.

View catalogue parameters and use notes
Appearance
Colourless to pale-yellow liquid
Solids
21–32%
Reference dose
About 1–20 ppm
Dosing point
Before the security filter

Dose depends on feed salinity, temperature, recovery and membrane type. Confirm compatibility with the membrane manufacturer's limits before start-up.

P-03Descaling

Industrial Scale Remover

Acid-based remover for hard scale, rust sludge and mixed deposits in heat exchangers, chillers, evaporative condensers, condensers and furnace water systems.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
pH (1%)
3.0 ± 0.5
Reference use
5–10% of system water inventory
Cleaning
pH 2–4, circulate 3–5 hours

Confirm equipment materials, deposit type and permitted acid-cleaning conditions first. After cleaning, neutralise, flush and assess whether prefilming is needed.

P-04Boiler

Boiler Scale Inhibitor

Controls hardness scaling in industrial and power boilers, hot-water exchangers and water-supply piping, and supports blowdown management.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
pH (1%)
2–8
Solids
21–32%
Operating note
Boiler water pH ≤ 12, regular blowdown

Can be dosed from the feed tank or directly into the boiler with a dosing unit. If water level behaves abnormally after blowdown, check for loosened old scale blocking piping.

P-05Membrane cleaning

Acid Cleaner

Removes acid-soluble fouling — carbonate, sulfate, iron oxide and mixed scale — from RO, hollow-fibre, NF and UF membranes and metal surfaces.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
pH (1%)
3.0 ± 0.5
Solids
21–35%
Reference dilution
1–3% of cleaning solution

Measure cleaning-solution pH every 5–20 minutes. Temperature and contact time must stay inside the membrane maker's limits; replace the bath when heavily loaded.

P-06CIP

Alkaline Cleaner

Removes oil, cutting fluid, drawing oil, lubricating grease and stamping residue from tanks, pipes, filling lines and pasteurisation equipment.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
pH (1%)
8–12
Solids
21–35%
CIP temperature
60–75 °C

Reference effective alkali 0.15–0.25% for general CIP and 0.35–0.55% for filling or pasteurisation equipment; verify against the equipment and product SDS.

P-07HVAC

HVAC Water Treatment Chemical

Scale and corrosion control for central-air-conditioning and industrial circulating water, including high-chloride and medium-to-high-alkalinity makeup water.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
Solids
35–40%
pH (1%)
3 ± 0.5
Reference dose
100–200 g per tonne of system water

Add at the cooling-tower sump before normal operation. Check compatibility with existing treatment chemicals before switching products.

P-08Copper

Copper Inhibitor

Forms a protective film on copper and copper alloys in circulating water and can be combined with selected scale inhibitors and biocides.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
Solids
35–40%
pH (1%)
3 ± 0.5
Reference
Dose set by water-quality review

Also listed for automotive coolant and lubricant additive use. Confirm the correct grade for the application and avoid mixing with incompatible additives.

P-09Heavy metals

Organic Sulfur

Chelating precipitant for heavy-metal ions in desulfurisation, metallurgy, electroplating and power-plant wastewater.

View catalogue parameters and use notes
Appearance
Slightly yellow liquid
Solids
≥ 15%
pH (1%)
10–13
Reference dose
20–40 ppm

Adjust wastewater to neutral or slightly alkaline before dosing, then add coagulant and flocculant as required. Dispose of metal-bearing cake under local rules.

P-10Heavy metals

Heavy Metal Catcher

Chelating agent that binds copper, lead, manganese, nickel, zinc and chromium into insoluble salts for electroplating, PCB, mine-tailings, metallurgy, chemical and leather wastewater.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
Solids
≥ 15%
Working pH
7–9
Reference method
Dilute to 1–2%, mix 5–10 min

Add coagulant/flocculant, settle about 10 minutes, then filter. Select the dose from a representative water sample rather than a generic figure.

P-11Biocide

Non-Oxidising Biocide

Microbiological control for RO systems, cooling towers, industrial storage water, fountains and landscape water, with penetration into slime layers.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
Solids
14–16%
pH (1%)
3 ± 0.5
RO reference
1–2 ppm continuous; 25–100 ppm intermittent

Alternate with other biocides to limit resistance. Check discharge limits and reduce dose when reducing agents are present.

P-12Biocide

Oxidising Biocide

Fast-acting microbiological control for industrial once-through and recirculating cooling water, plus sulphide removal and wastewater disinfection.

View catalogue parameters and use notes
Appearance
Pale-yellow clear liquid
pH (1%)
3 ± 0.5
Reference dose
About 100 ppm
Cycle
Set by site technical staff

Never mix or dose together with reducing agents. Drinking-water, food-contact or disinfectant use requires the correct grade and local approval.

P-13Biofilm

Slime Stripping Agent

Loosens biological slime, zoogloea and wall deposits in power, chemical, refinery, ammonia, urea and coking circulating-water systems.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
Solids
60%
pH (1%)
3 ± 0.5
Dose
Set by slime load and circulation

Check colony counts, slime volume, flow velocity and equipment limits first. After stripping, plan blowdown to avoid re-deposition.

P-14Nutrients

Phosphorus Removal Agent

Removes phosphate from municipal wastewater and from surface-treatment, food, pharmaceutical, paper, fertiliser and landfill-leachate effluent.

View catalogue parameters and use notes
Appearance
White powder
pH (1%)
4–6
Reference dose
100–1,000 ppm
Density
1.7 g/cm³ at 20 °C

Equivalent to 0.1–1 kg per tonne of wastewater. Dissolve to 10–20% where required and confirm the dose with a jar test.

P-15Colour

Decolourant

Colour removal for dye, textile, printing and dyeing, pigment, ink, paper and slaughterhouse wastewater.

View catalogue parameters and use notes
Appearance
Colourless clear liquid
Solids
30%
pH
3–5
Reference dose
0.05–0.3%

Dilute 10–40 times, adjust wastewater pH to about 4–12, dose before a suitable coagulant or PAM, and confirm the sequence with a jar test.

P-16Ammonia

Granular Ammonia Nitrogen Remover

For polishing or emergency adjustment of low-to-medium ammonia nitrogen wastewater from PCB, electroplating, textile, dyeing, leather, fertiliser and livestock operations.

View catalogue parameters and use notes
Appearance
White granular solid
pH (1%)
9.0–12.0
Density
1.27 g/cm³ at 20 °C
Reference
≈ 1 kg/t lowers NH₃-N by ≈ 100 mg/L

The figure is a catalog reference, not a guarantee. Screen doses in 200 mL samples at 100 ppm, 200 ppm and further gradients.

P-17Ammonia

Powdered Ammonia Nitrogen Remover

Powdered version of the ammonia nitrogen remover for the same wastewater targets, suited to preparing a metered dosing solution.

View catalogue parameters and use notes
Appearance
White powder
pH (1%)
9.0–12.0
Density
1.27 g/cm³ at 20 °C
Preparation
≈ 10% solution

Evaluate residual ammonia, pH, sludge production, coexisting oxidants and discharge compliance before full-scale dosing.

P-18Odour

Plant Deodoriser

Plant-derived deodoriser for spraying odour sources in wastewater, solid-waste, landfill, livestock, aquaculture, food and pharmaceutical facilities.

View catalogue parameters and use notes
Appearance
Colourless to pale-yellow liquid
Solids
≥ 15%
pH (1%)
3–5
Use
Dilute and spray on the odour source

Source control and ventilation remain necessary. Assess performance with ammonia, hydrogen sulphide or sensory indicators, not appearance alone.

P-19Foam

Silicone Defoamer

Silicone antifoam for wastewater, paper, textile sizing, industrial cleaning, PCB, chemical, electroplating, dyeing, pharmaceutical, coating and fermentation foam.

View catalogue parameters and use notes
Appearance
Milky-white liquid
Solids
≥ 14.5%
pH (1%)
3 ± 0.5
Dilution
Thickened water, 30–60 rpm, ≤ 10 min

Choose an addition point where foam forms and the product disperses well. Confirm the ratio on the actual foaming system.

P-20Reducing

Reducing Agent (Sodium Sulfite)

Sodium sulfite reducing agent for dechlorination, reduction and selected textile, dyeing, leather, chemical and photographic processes.

View catalogue parameters and use notes
Appearance
White powder
Assay
96%
Solids
≥ 80%
pH (1%)
3–5

Check the grade and regulatory permission before any food, drinking-water or other regulated use. Keep away from oxidisers.

P-21Prefilming

Prefilming Agent

Forms a protective film on cleaned pipes and heat-exchange equipment before the system returns to normal service.

View catalogue parameters and use notes
Appearance
Colourless to pale-yellow liquid
pH (1%)
7–9
Density
1.05–1.15 g/cm³ at 20 °C
Key variables
Cleanliness, pH, temperature, flow

Film quality depends on surface cleanliness, contact time and flow. Prefilm immediately after cleaning and before the corrosion-inhibitor programme starts.

P-22FGD

Desulfurisation Synergist

Process additive for wet flue-gas desulfurisation, evaluated against flue-gas flow, SO₂ concentration, slurry chemistry, pH and equipment conditions.

View catalogue parameters and use notes
Appearance
White powder
pH (1%)
9.0–12.0
Density
1.27 g/cm³ at 20 °C
Reference
Wastewater jar test ≈ 1 kg/t for ≈ 100 mg/L

The wastewater jar-test figure is not a flue-gas design guarantee. Supplement it with site SO₂ balance and slurry data.

DOSING & VERIFICATION

Dosing starts with a water report.

"How much per tonne" is an outcome, not a selection basis. Run trials and site verification in the order below and record the raw data — do not judge performance from colour, foam or a single test.

Send water and process data
  1. 01

    Define the target

    State whether the problem is scaling rate, corrosion, residual metals, ammonia, total phosphorus, colour, foam or odour, and how each will be measured.

  2. 02

    Provide the full water analysis

    pH, temperature, hardness, alkalinity, salinity, turbidity, COD, target pollutants, coexisting ions and treatment flow.

  3. 03

    Run compatibility and jar tests

    Establish dosing order, dilution, mixing time, settling rate and optimum pH, and watch for abnormal foam or precipitation.

  4. 04

    Gradient dose and monitor on site

    Start conservatively, record indicators before and after, and avoid over-dosing that causes secondary pollution, scaling or corrosion.

HANDLING & SAFETY

Correct use matters
more than "adding more".

Read the TDS and SDS first

Different concentrations, batches and formulations are not interchangeable. Check product name, solids, pH, packaging, shelf life and intended application before use.

Prevent incompatible mixing

Store oxidisers and reducing agents, acids and alkalis, and different metal-treatment chemicals separately and dose them separately. Run a compatibility test before any mixing.

Protect people and provide washing

Avoid skin and eye contact. Follow the SDS for gloves, goggles and protective clothing; flush with plenty of water after contact and follow the site emergency procedure.

Dispose of effluent and sludge legally

Cleaning effluent, metal-bearing precipitate and chemical sludge must go to a compliant treatment system or licensed disposal — never discharged without assessment.

Scope of performance: the parameters on this page come from the product catalogue and are intended for first screening and inquiry preparation. Actual results depend on water-quality variation, dosing control, equipment condition and operating practice, and must be confirmed by representative-sample trials and a formal technical proposal.

FREQUENTLY ASKED QUESTIONS

Product selection questions

These answers cover the information needed to prepare a useful inquiry and are written for procurement teams and AI search engines alike.

How do I choose a corrosion and scale inhibitor for a cooling water system?

Start with makeup and circulating water data: hardness, alkalinity, chloride, pH, conductivity, turbidity, system materials and holding volume. Then decide whether calcium carbonate, calcium sulfate or calcium phosphate scaling dominates, or whether carbon-steel and copper corrosion is the main risk. The catalog reference dose for the corrosion and scale inhibitor is 10–30 mg/L on makeup water, still subject to water quality and product version.

Where and at what dose should RO antiscalant be dosed?

Dose before the security filter unless the system design specifies another point. The catalog reference range is about 1–20 ppm; the actual figure depends on feed salinity, temperature, recovery, membrane type and scaling potential.

Why can't you quote one fixed dose for every plant?

Contaminant concentration, pH, temperature, contact time, mixing and system load all change reaction efficiency, and products with the same generic name can have different concentrations. A catalog figure is a starting point; the operating dose is confirmed by a jar test and site monitoring.

Scale and corrosion appear at the same time — which do I treat first?

Check heat-transfer efficiency, differential pressure, corrosion rate, iron and copper content, water-stability indices and surface condition together. High temperature with hard water usually points to scaling; low pH, high chloride or high velocity points to corrosion. A corrosion and scale inhibitor, copper inhibitor and prefilming agent can be combined when both risks exist.

What is the difference between organic sulfur and a heavy metal catcher?

Both precipitate heavy metals, but their reactive groups, working pH and dosing conditions differ. Organic sulfur is commonly used in desulfurisation, metallurgy, electroplating and power-plant wastewater with a catalog reference of 20–40 ppm; the heavy metal catcher is positioned around copper, lead, nickel, zinc and chromium chelation. Select between them with the actual wastewater sample.

Can an ammonia nitrogen remover replace biological treatment?

No. The product is intended for polishing or emergency adjustment of some low-to-medium concentration streams. Assess influent ammonia, target value, pH, residual chlorine, coexisting ions, sludge production and long-term operating cost first, then confirm with a gradient test.

How should I run a jar test for phosphorus removal and decolourisation?

For phosphorus, prepare a dose gradient at the same pH and mixing conditions, then measure residual total phosphorus. For colour, record initial colour, pH, COD, dosing sequence and settling time. Both are usually combined with coagulant and PAM, so judge more than a single visual change.

Should I use an oxidising or a non-oxidising biocide?

Oxidising products act quickly and suit high microbial load or specific disinfection duties. Non-oxidising products penetrate slime better and are less affected by reducing substances. Never mix them, and alternate programmes to reduce microbial resistance.

When is a slime stripping agent appropriate?

When cooling towers, condensers, piping or membranes show biological slime, zoogloea or under-deposit corrosion risk. Check colony counts, slime volume, flow velocity and equipment limits first, and plan blowdown to avoid secondary deposition.

Acid cleaner or alkaline cleaner — which one?

Acid cleaners target carbonate, sulfate and iron-oxide scale; alkaline cleaners target oil, organic matter and some biological fouling. Before membrane cleaning, confirm the membrane maker's pH, temperature and pressure limits and measure the cleaning solution pH.

How is silicone defoamer diluted and added?

The catalog suggests thickened water at 30–60 rpm for no more than 10 minutes. Add at a point where foam has formed and the product disperses well; confirm the final ratio on the actual foaming system.

Is a plant deodoriser just covering the smell?

The catalog describes plant-derived components that adsorb, mask or react with ammonia, hydrogen sulphide and some organic odours. Source control, collection and ventilation still come first, and performance should be judged on ammonia, hydrogen sulphide or sensory indicators.

What information do I need to send for a quotation?

Application, water source or wastewater type, treatment flow in m³/day, pH, temperature, turbidity, hardness, alkalinity, conductivity, COD, target pollutant and target value, equipment or membrane material, current process, current chemical and problem, discharge standard, destination country and required sample quantity.

How are the products packaged and stored?

Liquids are commonly supplied in 25 kg drums and powders or granules in 25 kg bags, with project-specific packaging possible. Store cool and dry, away from sunlight, frost and incompatible materials. Catalog shelf life is typically 12 months; the batch label and SDS govern.

Can I order a sample or obtain the TDS and SDS?

Yes — request the product in the inquiry form and state the required sample volume, application and the membrane or equipment material. Technical documents, samples and formal quotations are confirmed against the specific product version, project location and delivery terms.

What about the chemical formula, MSDS, HS code and price of the RO antiscalant?

RO antiscalants are blended products, so no single chemical formula represents every grade. Check the TDS and SDS of the exact model, and confirm the HS code from the active ingredients, use, packaging and destination country. Price depends on specification, quantity, packaging, lead time and delivery point, so it is quoted per project.

What is the English name and composition of the heavy metal catcher?

It is usually called a heavy metal catcher, heavy metal chelating agent or heavy metal precipitant. Different products use different chelating or precipitation groups; composition and content must come from the model-specific TDS, SDS and sample label, not from the generic name.

How is ammonia nitrogen removed from wastewater, and when does a remover apply?

Depending on concentration and process, ammonia nitrogen is handled by biological nitrification/denitrification, stripping, breakpoint chlorination or other polishing steps. An ammonia nitrogen remover suits some low-to-medium concentration polishing or emergency cases, but influent ammonia, target, pH, residual chlorine, coexisting pollutants and sludge impact must be checked first.

REQUEST A PRODUCT RECOMMENDATION

Send the water problem,
start from data.

Describe the treatment target, system type and water conditions to receive product documents, sample advice and the next test step.

Phone / WhatsApp+86 132 6287 9223
Emailrisinn@shcronus.com
AddressRoom 801, Building 2, Shanghai Zhicheng,
No. 8666 Hunan Highway, Pudong New Area, Shanghai, China
Water treatment chemical drums ready for dispatch

Submitting opens your chosen WhatsApp or email client. The form is not uploaded by this page; confirm the message in the new chat or email window.

WhatsApp